Markalar
Ürünleri Markalara göre sınırlayın
Temsilciliklerimiz:
Badger Meter Labom AquaMetrix cs Racine Dynasonic preso hedland Blancett flo-tech cox
  • Flow sensör 228 PV

Flow sensör 228 PV

Çok yönlü uygulamalar için

 

  • In PVC T-type
  • To be glued in a PVC pipe system
  • Suited for corrosive fluids
Medium:
Water, Pharmaceutical media
max. flow:
from 12 up to 4200 l/min
Temperature:
from 0 up to 60 °C
max. pressure:
from 0 up to 10 bar
Branch:
Water & waste water industry, Chemical industry, HVAC

 

General information

These models feature a modified PVC tee with solvent weld socket end connections and a removable, PPS or PVDF sensor insert. Sizes of 1 1/2", 2", 3" and 4" are available.

 

Technical data

Mounting in pipe sizes DN 32 – 100 / 1,5 – 4“
Flow range in m/s (standard) 0,15 – 9
Flow range in m/s (low flow) -
Accuracy (full scale / Qmax.) ±1 %
Accuracy (of reading) -
Repeatability (full scale / Qmax.) ±0,3 %

 

Measuring principle

Impeller meters


Impeller meters

The series feature a six-bladed impeller design with a proprietary, non-magnetic sensing mechanism. The impeller shape coupled with the absence of magnetic drag provides accuracy and repeatability throughout the flow range of the sensors. As the liquid flow turns the impeller, a low impedance square wave signal is transmitted with a frequency proportional to the flow rate.