Temsilciliklerimiz:
Flow sensör 228 PV
Çok yönlü uygulamalar için
- In PVC T-type
- To be glued in a PVC pipe system
- Suited for corrosive fluids
Medium:
Water, Pharmaceutical media
Water, Pharmaceutical media
max. flow:
from 12 up to 4200 l/min
from 12 up to 4200 l/min
Temperature:
from 0 up to 60 °C
from 0 up to 60 °C
max. pressure:
from 0 up to 10 bar
from 0 up to 10 bar
Branch:
Water & waste water industry, Chemical industry, HVAC
Water & waste water industry, Chemical industry, HVAC
General information
These models feature a modified PVC tee with solvent weld socket end connections and a removable, PPS or PVDF sensor insert. Sizes of 1 1/2", 2", 3" and 4" are available.
Technical data
| Mounting in pipe sizes DN | 32 – 100 / 1,5 – 4“ |
| Flow range in m/s (standard) | 0,15 – 9 |
| Flow range in m/s (low flow) | - |
| Accuracy (full scale / Qmax.) | ±1 % |
| Accuracy (of reading) | - |
| Repeatability (full scale / Qmax.) | ±0,3 % |
Measuring principle
Impeller meters

The series feature a six-bladed impeller design with a proprietary, non-magnetic sensing mechanism. The impeller shape coupled with the absence of magnetic drag provides accuracy and repeatability throughout the flow range of the sensors. As the liquid flow turns the impeller, a low impedance square wave signal is transmitted with a frequency proportional to the flow rate.